Objective To evaluate the BacT/ALERT 3D liquid culture technology on the detection of drug resistance of Mycobacterium tuberculosis(MTB)and to compare the difference between this technology and Lowenstein -Jensen (L -J) proportion method.Methods BacT/ALERT 3D liquid culture technology and L -J proportion technology were applied to detect the drug resistance of tuberculosis from the positive cultures of 219 solid culture samples.Results The average detection time of BacT/ALERT 3D method was 8.02 ±3.85 d,which was about 20 days shorter than that of L -J proportion method.60 drug resistance strains were found using BacT/ALERT 3D technology,While 79 drug resistance strains were found using L -J proportion technology.There showed no significant difference (P >0.05).The compliance rate of BacT/ALERT 3D method and L -J proportion method on the anti -tuberculosis drugs INH,RFP,EMB and SMwas 95.43%,92.69%,95.43% and 92.24% respectively.Conclusion BacT/ALERT 3D liquid culture technology could detect drug resistant TB strains rapidly with high concordance with the results of L -J proportion method on anti -tuberculosis drugs.